Kritik Hastada Ultrasonografik Volüm Değerlendirmesi

Authors

Sercan Yalçınlı

Synopsis

Although fluid therapy is often the initial approach to achieve hemodynamic stability in critically ill emergency department patients, inappropriate and excessive fluid administration can lead to severe complications such as increased mortality, ARDS, prolonged mechanical ventilation, and acute kidney injury, while inadequate volume replacement results in tissue hypoxia. Therefore, accurate assessment of patients' volume status and fluid responsiveness is of critical importance. Traditional static methods, such as central venous pressure and pulmonary artery catheterization, have been replaced by dynamic monitoring techniques based on the Frank-Starling curve due to their invasive nature and conflicting results. Currently, ultrasonography stands out as a non-invasive, reliable, and practical tool for evaluating intravascular volume status in critically ill patients. Ultrasonographic evaluation allows for the measurement of stroke volume and cardiac output via left ventricular outflow tract (LVOT) diameter and aortic velocity time integral (VTI). Subaortic VTI and carotid flow variations combined with the passive leg raising test—a reversible preload-increasing technique—predict fluid responsiveness with high sensitivity. Additionally, main carotid artery ultrasonography enables the evaluation of corrected flow time and respiratory variation in peak systolic velocity. Although inferior vena cava (IVC) respiratory diameter variations are commonly used, clinicians must consider potential false results caused by mechanical ventilation settings, forced respiratory efforts, intra-abdominal pressure, and right ventricular dysfunction.

References

S. T. Micek, C. McEvoy, M. McKenzie, N. Hampton, J. A. Doherty, and M. H. Kollef, “Fluid balance and cardiac function in septic shock as predictors of hospital mortality,” Crit. Care, vol. 17, no. 5, p. R246, Oct. 2013.

M. Jozwiak et al., “Extravascular lung water is an independent prognostic factor in patients with acute respiratory distress syndrome,” Crit. Care Med., vol. 41, no. 2, pp. 472–480, Feb. 2013.

P. E. Marik, M. Baram, and B. Vahid, “Does Central Venous Pressure Predict Fluid Responsiveness?: A Systematic Review of the Literature and the Tale of Seven Mares,” Chest, vol. 134, no. 1, pp. 172–178, Jul. 2008.

X. Monnet, P. E. Marik, and J.-L. Teboul, “Prediction of fluid responsiveness: an update,” Ann. Intensive Care, vol. 6, no. 1, p. 111, Dec. 2016.

X. Monnet et al., “Passive leg raising predicts fluid responsiveness in the critically ill,” 2006.

M. Slama and J. Maizel, “Assessment of Fluid Requirements: Fluid Responsiveness,” in Hemodynamic Monitoring Using Echocardiography in the Critically Ill, Berlin, Heidelberg: Springer Berlin Heidelberg, 2011, pp. 61–69.

M. Slama, J. Maizel, Assessment of Fluid Requirements: Fluid Responsiveness in “Hemodynamic Monitoring Using Echocardiography in the Critically Ill”. D.D. Backer, M. Slama, Philippe Vignon, Bernard P. Cholley. Springer Berlin Heidelberg, 2011, pp. 61–69

M. Sidor, L. Premachandra, B. Hanna, N. Nair, and A. Misra, “Carotid Flow as a Surrogate for Cardiac Output Measurement in Hemodynamically Stable Participants,” J. Intensive Care Med., p. 088506661877569, May 2018.

D. C. Mackenzie et al., “Carotid Flow Time Changes With Volume Status in Acute Blood Loss.,” Ann. Emerg. Med., vol. 66, no. 3, pp. 277-282.e1, Sep. 2015.

H. Shokoohi et al., “The diagnostic utility of sonographic carotid flow time in determining volume responsiveness,” J. Crit. Care, vol. 38, pp. 231–235, Apr. 2017.

M. Á. Ibarra-Estrada, J. A. López-Pulgarín, J. C. Mijangos-Méndez, J. L. Díaz-Gómez, and G. Aguirre-Avalos, “Respiratory variation in carotid peak systolic velocity predicts volume responsiveness in mechanically ventilated patients with septic shock: a prospective cohort study,” Crit. Ultrasound J., vol. 7, no. 1, p. 12, Dec. 2015.

M. Alavi-Moghaddam, A. Kabir, M. Shojaee, M. Manouchehrifar, and M. Moghimi, “Ultrasonography of inferior vena cava to determine central venous pressure: a meta-analysis and meta-regression,” Acta radiol., vol. 58, no. 5, pp. 537–541, May 2017.

E. Long, E. Oakley, T. Duke, and F. E. Babl, “Does Respıratory Varıatıon In Inferıor Vena Cava Dıameter Predıct Fluıd Responsıveness: A Systematıc Revıew And Meta-Analysıs” Shock. May;47(5):550-559. 2017

L. Muller et al., “Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use” Crit Care. 2012 Oct 8;16(5):R188.2012.

Z. Zhang, X. Xu, S. Ye, and L. Xu, “Ultrasonographic Measurement of the Respiratory Variation in the Inferior Vena Cava Diameter Is Predictive of Fluid Responsiveness in Critically Ill Patients: Systematic Review and Meta-analysis,” Ultrasound Med. Biol., vol. 40, no. 5, pp. 845–853, May 2014.

D. Evans, G. Ferraioli, J. Snellings, and A. Levitov, “Volume responsiveness in critically III patients,” J. Ultra-sound Med. vol:33, no:1, pp.3-7, January 2014.

G. Via, G. Tavazzi, and S. Price, “Ten situations where inferior vena cava ultrasound may fail to accurately predict fluid responsiveness: a physiologically based point of view,” Intensive Care Med., vol. 42, no. 7, pp. 1164–1167, Jul. 2016.

Pages

453-459

Published

November 12, 2021

License

License