REJYONEL ANESTEZI VE AKUT AĞRI TIBBININ TEMELLERI: Ekipman

Authors

Gülay Kip

Synopsis

The selection and proper use of equipment in regional anesthesia and acute pain medicine, combined with the practitioner's anatomical knowledge, maximizes clinical success. Single-use sterile block trays enhance quality while minimizing infection risks. Peripheral nerve stimulators deliver electrical current to elicit painless muscle contractions for nerve localization by stimulating motor fibers at 0.1 ms, whereas 0.3 ms duration is preferred for sensory fibers. Insulated echogenic needles concentrate current density at their tips, allowing more precise localization. Ultrasound machines alongside linear or curved transducers enable direct, high-resolution visualization of peripheral nerves and fascicles. Small-volume injections (0.5–1 mL) of saline, local anesthetic, or air are utilized to improve the visibility of needle tips and catheters. Power Doppler provides high sensitivity for identifying small arteries accompanying nerves and intraneural blood flow, while spatial compound imaging reduces technical artifacts. For continuous or ambulatory infusions, elastomeric or battery-operated mechanical pumps deliver safe postoperative analgesia. Ultimately, it must be noted that no localization technique completely eliminates the risk of nerve injury.

References

Perlas A, Niazi A, McCartney C, et al. The sensitivity of motor response to nerve stimulation and paresthesia for nerve localization as evaluated by ultrasound. Reg Anesth Pain Med 2006;31(5):445–450.

Tsui BC, Wagner A, Finucane B. Electrophysiologic effect of injectates on peripheral nerve stimulation. Reg Anesth Pain Med 2004;29(3):189–193.

Wynd KP, Smith HM, Jacob AK, et al. Ultrasound machine comparison: an evaluation of ergonomic design, data management, ease of use, and image quality. Reg Anesth Pain Med 2009;34(4):349–356.

Szabo TL, Lewin PA. Ultrasound transducer selection in clinical imaging practice. J Ultrasound Med. 2013;32(4):573–582.

Rubin JM, Bude RO, Carson PL, et al. Power Doppler US: a potentially useful alternative to mean frequencybased color Doppler US. Radiology 1994;190(3):853–856.

Vanderschueren GA, Meys VE, Beekman R. Doppler sonography for the diagnosis of carpal tunnel syndrome: a critical review. Muscle Nerve 2014;50(2):159–163.

Wilhjelm JE, Jensen MS, Jespersen SK, et al. Visual and quantitative evaluation of selected image combination schemes in ultrasound spatial compound scanning. IEEE Trans Med Imaging 2004;23(2):181–190.

Wiesmann T, Bornträger A, Zoremba M, et al. Compound imaging technology and echogenic needle design: effects on needle visibility and tissue imaging. Reg Anesth Pain Med 2013;38(5):452–455.

Goldstein A, Ranney D, McLeary RD. Linear array test tool. J Ultrasound Med 1989;8:385–397.

Lin DC, Nazarian LN, O’Kane PL, et al. Advantages of real-time spatial compound sonography of the musculoskeletal system versus conventional sonography. AJR Am J Roentgenol 2002;179(6):1629–1631.

Provenzano DA, Liebert MA, Steen B, et al. Investigation of current infection-control practices for ultrasound coupling gel: a survey, microbiological analysis, and examination of practice patterns. Reg Anesth Pain Med 2013;38(5):415–424.

Alakkad H, Naeeni A, Chan VW, et al. Infection related to ultrasound-guided single-injection peripheral nerve blockade: a decade of experience at Toronto Western hospital. Reg Anesth Pain Med 2015;40(1):82–84.

Pintaric TS, Cvetko E, Strbenc M, et al. Intraneural and perineural inflammatory changes in piglets after inject of ultrasound gel, endotoxin, 0.9% NaCl, or needle insertion without injection. Anesth Analg 2014;118(4):869–873.

Tsui BC. Dextrose 5% in water as an alternative medium to gel for performing ultrasound-guided peripheral nerve blocks. Reg Anesth Pain Med 2009;34(5):525–527.

Tsui BC, Twomey C, Finucane BT. Visualization of the brachial plexus in the supraclavicular region using a curved ultrasound probe with a sterile transparent dressing. Reg Anesth Pain Med 2006;31(2):182–184.

Schafhalter-Zoppoth I, McCulloch CE, Gray AT. Ultrasound visibility of needles used for regional nerve block: an in vitro study. Reg Anesth Pain Med 2004;29(5):480–488.

McGahan JP. Laboratory assessment of ultrasonic needle and catheter visualization. J Ultrasound Med 1986;5:373–377.

Mariano ER, Yun RD, Kim TE, et al. Application of echogenic technology for catheters used in ultrasoundguided continuous peripheral nerve blocks. J Ultrasound Med 2014;33(5):905–911.

Takatani J, Takeshima N, Okuda K, et al. Ultrasound visibility of regional anesthesia catheters: an in vitro study. Korean J Anesthesiol 2012;63(1):59–64.

Swenson JD, Davis JJ, DeCou JA. A novel approach for assessing catheter position after ultrasound-guided placement of continuous interscalene block. Anesth Analg 2008;106(3):1015–1016.

Kan JM, Harrison TK, Kim TE, et al. An in vitro study to evaluate the utility of the “air test” to infer perineural catheter tip location. J Ultrasound Med 2013;32(3):529–533.

Dhir S, Ganapathy S. Use of ultrasound guidance and contrast enhancement: a study of continuous infraclavicular brachial plexus approach. Acta Anaesthesiol Scand 2008;52(3):338–342.

Brookes J, Sondekoppam R, Armstrong K, et al. Comparative evaluation of the visibility and block characteristics of a stimulating needle and catheter vs an echogenic needle and catheter for sciatic nerve block with a low-frequency ultrasound probe. Br J Anaesth 2015;115(6):912–919.

Elsharkawy H, Salmasi V, Abd-Elsayed A, et al. Identification of location of nerve catheters using pumping maneuver and M-Mode – a novel technique. J Clin Anesth 2015;27(4):325–330.

Published

May 18, 2021

License

License