Toksikolojik Analizler İçin Kromatografik Kütüphanelere Güncel Yaklaşımlar
Synopsis
In analytical toxicology, the use of liquid chromatography-mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS)-based methods coupled with mass spectral libraries is rapidly increasing for the simultaneous detection of xenobiotics as well as new legal and illicit substances. Although traditional Gas Chromatography-Mass Spectrometry (GC-MS) provides standard and extensive libraries owing to its stable ionization energy (70 eV), it requires time-consuming derivatization steps for non-volatile, polar, and thermally labile compounds. In contrast, LC-MS systems facilitate the sensitive screening and identification of high-molecular-weight and polar compounds without requiring derivatization. Online spectral libraries are constructed by combining product-ion spectra acquired at different collision energies (e.g., 20, 35, 50 eV) or composite spectra. Furthermore, untargeted screening is performed on high-resolution mass spectrometers (HRMS) using data-independent analysis (DIA) and data-dependent analysis (DDA) modes. Accurate compound identification relies on relative retention time (RRT) tolerances, ion intensity ratios, structurally specific fragment ions, and similarity scores calculated via Bayesian or NIST algorithms. Nevertheless, methodological limitations such as matrix-induced ion suppression, inter-instrument geometric differences, contaminants, and co-fragmentation hamper cross-platform library transferability. Ultimately, while advanced software and library searching greatly streamline analytical workflows, the final confirmation and diagnosis depend on the visual spectrum comparison and expertise of an experienced analytical toxicologist.
References
Maurer HH. Multi-analyte procedures for screening for and quantification of drugs in blood, plasma, or serum by liquid chromatography-single stage or tandem mass spectrometry (LC-MS or LC-MS/MS) relevant to clinical and forensic toxicology. Vol. 38, Clinical Biochemistry. Elsevier Inc.; 2005. p. 310–8.
Hernández F, Ibáñez M, Bade R, Bijlsma L, Sancho J V. Investigation of pharmaceuticals and illicit drugs in waters by liquid chromatography-high-resolution mass spectrometry. Vol. 63, TrAC - Trends in Analytical Chemistry. Elsevier B.V.; 2014. p. 140–57.
Ojanperä I, Kolmonen M, Pelander A. Current use of high-resolution mass spectrometry in drug screening relevant to clinical and forensic toxicology and doping control [Internet]. Vol. 403, Analytical and Bioanalytical Chemistry. Springer; 2012 [cited 2021 Apr 5]. p. 1203–20. Available from: https://link.springer.com/article/10.1007/s00216-012-5726-z
Weinmann W, Stoertzel M, Vogt S, Svoboda M, Schreiber A. Tuning compounds for electrospray ionization/in-source collision-induced dissociation and mass spectra library searching. J Mass Spectrom [Internet]. 2001 Sep 1 [cited 2021 Apr 5];36(9):1013–23. Available from: http://doi.wiley.com/10.1002/jms.201
Schreiber A, Efer J, Engewald W. Application of spectral libraries for high-performance liquid chromatography-atmospheric pressure ionisation mass spectrometry to the analysis of pesticide and explosive residues in environmental samples. In: Journal of Chromatography A. Elsevier; 2000. p. 411–25.
Mueller CA, Weinmann W, Dresen S, Schreiber A, Gergov M. Development of a multi-target screening analysis for 301 drugs using a QTrap liquid chromatography/tandem mass spectrometry system and automated library searching. Rapid Commun Mass Spectrom. 2005;19(10):1332–8.
Wohlfarth A, Scheidweiler KB, Chen X, Liu H-F, Huestis MA. Qualitative Confirmation of 9 Synthetic Cannabinoids and 20 Metabolites in Human Urine Using LC−MS/MS and Library Search. 2013 [cited 2021 Apr 20]; Available from: https://pubs.acs.org/sharingguidelines
Oberacher H, Pavlic M, Libiseller K, Schubert B, Sulyok M, Schuhmacher R, et al. On the inter-instrument and inter-laboratory transferability of a tandem mass spectral reference library: 1. Results of an austrian multicenter study. J Mass Spectrom [Internet]. 2009 Apr 1 [cited 2021 Jun 6];44(4):485–93. Available from: www.interscience.com
Martinez RI, Boyd RK. Instrument‐independent tandem mass spectrometry database for XQQ instruments: The dynamical prerequisites. Rapid Commun Mass Spectrom [Internet]. 1988 Jan 1 [cited 2021 Jun 6];2(1):8–13. Available from: https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/full/10.1002/rcm.1290020104
Fabresse N, Larabi IA, Stratton T, Mistrik R, Pfau G, Lorin de la Grandmaison G, et al. Development of a sensitive untargeted liquid chromatography–high resolution mass spectrometry screening devoted to hair analysis through a shared MS2 spectra database: A step toward early detection of new psychoactive substances. Drug Test Anal [Internet]. 2019 May 25 [cited 2021 Apr 5];11(5):697–708. Available from: https://onlinelibrary.wiley.com/doi/abs/10.1002/dta.2535
Oberacher H, Whitley G, Berger B. Evaluation of the sensitivity of the “Wiley registry of tandem mass spectral data, MSforID” with MS/MS data of the “NIST/NIH/EPA mass spectral library.” J Mass Spectrom [Internet]. 2013 Apr 1 [cited 2021 Jun 8];48(4):487–96. Available from: https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/full/10.1002/jms.3184
Fred W. McLafferty DBS. Wiley/NBS Kütle Spektral Veri Kaydı - 1989 - Wiley Analytical Science [Internet]. [cited 2021 Jun 8]. Available from: https://analyticalscience.wiley.com/do/10.1002/sepspec.9780471628866
Rivier L. Criteria for the identification of compounds by liquid chromatography-mass spectrometry and liquid chromatography-multiple mass spectrometry in forensic toxicology and doping analysis. Vol. 492, Analytica Chimica Acta. Elsevier; 2003. p. 69–82.
Stein SE, Scott DR. Optimization and testing of mass spectral library search algorithms for compound identification. J Am Soc Mass Spectrom [Internet]. 1994 [cited 2021 Jun 8];5(9):859–66. Available from: https://link.springer.com/article/10.1016/1044-0305(94)87009-8
Pavlic M, Libiseller K, Oberacher H. Combined use of ESI-QqTOF-MS and ESI-QqTOF-MS/MS with mass-spectral library search for qualitative analysis of drugs. In: Analytical and Bioanalytical Chemistry [Internet]. Springer; 2006 [cited 2021 Jun 6]. p. 69–82. Available from: https://link.springer.com/article/10.1007/s00216-006-0634-8
Gergov M. Library search-based drug analysis in forensic toxicology by liquid chromatography–mass spectrometry [Internet]. 2004 [cited 2021 Apr 24]. Available from: https://aaltodoc.aalto.fi/handle/123456789/2443
Gergov M, Ojanperä I, Vuori E. Simultaneous screening for 238 drugs in blood by liquid chromatography-ionspray tandem mass spectrometry with multiple-reaction monitoring. J Chromatogr B Anal Technol Biomed Life Sci. 2003 Sep 25;795(1):41–53.
Dresen S, Kempf J, Weinmann W. Electrospray-ionization MS/MS library of drugs as database for method development and drug identification. Forensic Sci Int. 2006 Sep 12;161(2–3):86–91.
Rochat B. Proposed Confidence Scale and ID Score in the Identification of Known-Unknown Compounds Using High Resolution MS Data. J Am Soc Mass Spectrom [Internet]. 2017 Apr 1 [cited 2021 Jun 9];28(4):709–23. Available from: https://pubmed.ncbi.nlm.nih.gov/28116700/
wada. World Anti Doping Agency | wada_td2015idcr_minimum_criteria_chromato-mass_spectro_conf_en.pdf [Internet]. [cited 2021 Jun 9]. Available from: https://wada-main-prod.s3.amazonaws.com/resources/files/wada_td2015idcr_minimum_criteria_chromato-mass_spectro_conf_en.pdf
COMMISSION DECISION. (2002/657/EC)-Official Journal of the European Communities. 2002.
Stein S. Mass spectral reference libraries: An ever-expanding resource for chemical identification. Anal Chem [Internet]. 2012 Sep 4 [cited 2021 Jun 8];84(17):7274–82. Available from: https://pubs.acs.org/sharingguidelines
Johnson J V, Yost RA, Kelley PE, Bradford DC. Tandem-in-Space and Tandem-in-Time Mass Spectrometry: Triple Quadrupoles and Quadrupole Ion Traps [Internet]. Anal. Chem. 1990 [cited 2021 Jun 6]. Available from: https://pubs.acs.org/sharingguidelines
Jansen R, Lachatre G, Marquet P. LC-MS/MS systematic toxicological analysis: Comparison of MS/MS spectra obtained with different instruments and settings. Clin Biochem. 2005 Apr 1;38(4):362–72.
Bristow AWT, Webb KS, Lubben AT, Halket J. Reproducible product-ion tandem mass spectra on various liquid chromatography/mass spectrometry instruments for the development of spectral libraries. Rapid Commun Mass Spectrom [Internet]. 2004 Jul 15 [cited 2021 Jun 6];18(13):1447–54. Available from: www.interscience.wiley.com
Maurer HH. Hyphenated mass spectrometric techniques - Indispensable tools in clinical and forensic toxicology and in doping control [Internet]. Vol. 41, Journal of Mass Spectrometry. Wiley InterScience; 2006 [cited 2021 Jun 6]. p. 1399–413. Available from: www.interscience.wiley.com
Milman BL. Towards a full reference library of MSn spectra. Testing of a library containing 3126 MS2 spectra of 1743 compounds. Rapid Commun Mass Spectrom [Internet]. 2005 Oct 15 [cited 2021 Jun 6];19(19):2833–9. Available from: www.interscience.wiley.com
Aebi B, Bernhard W. Advances in the use of mass spectral libraries for forensic toxicology. J Anal Toxicol [Internet]. 2002 Apr 1 [cited 2021 Jun 8];26(3):149–56. Available from: https://academic.oup.com/jat/article/26/3/149/760223
Maurer HH. What is the future of (ultra) high performance liquid chromatography coupled to low and high resolution mass spectrometry for toxicological drug screening? Vol. 1292, Journal of Chromatography A. 2013. p. 19–24.
Gergov M, Weinmann W, Meriluoto J, Uusitalo J, Ojanperä I. Comparison of product ion spectra obtained by liquid chromatography/triple-quadrupole mass spectrometry for library search. Rapid Commun Mass Spectrom [Internet]. 2004 May 30 [cited 2021 Jun 8];18(10):1039–46. Available from: www.interscience.wiley.com
Maciej J. Bogusz, Rolf-Dieter Maier , Klaus D. Kruger , Kenneth S. Webb ,bcJulie Romeril MLM. Poor reproducibility of in-source collisional atmospheric pressureionization mass spectra of toxicologically relevant drugs [Internet]. 1999 [cited 2021 Jun 8]. Available from: https://reader.elsevier.com/reader/sd/pii/S002196739900312X?token=ED16CF69BC922EF5790D9A1857D7C704229F736E325797D5CD7B58710F69BEE51EE238BD4B78EC15E865AC4AD160C566&originRegion=eu-west-1&originCreation=20210608112801